Omomierz o Szerokim PAS-853B
Wybierz swój język
To zmieni język opisu tego produktu. To nie zmieni języka strony ani opisów innych produktów.
  • Omomierz o Szerokim PAS-853B
    Pozwala na pomiar oporności w zakresie od 0,01 Ω aż do 9,99x1012
    • Wide Resistance Measurement Range from 0.01 ohm to 9.99x1012 ohms
    • Nominal Full Range Tolerance Averages <±5%
    • Fully Automatic Resistance Range, Test Voltage and Electrification Period control
    • Automatic or Continuous Electrification Control
    • Rugged High Performance 80 inches (200cm) Test Leads
    • Powered by one long lasting 9V alkaline battery
    • Large, easy to read LCD Display
    • Meets requirements of ESD Association Standards for material and audit resistance measurement requirements
    • Certificate of Calibration Traceable to NIST included
    PAS-853B – omomierz o szerokim zakresie pomiarowym ułatwiający spełnienie wymagań ANSI/ESD S20.20. Pozwala na pomiar oporności w zakresie od 0,01 Ω aż do 9,99·1012Ω (10 TΩ) z rewelacyjną dokładnością lepszą niż ±5%. Miernik sam dobiera zakres pomiarowy, napięcie pomiarowe (do 100 V) oraz szybkość pomiarów, aby zapewnić wynik o najlepszej dokładności.

    Realizuje automatyczne okresowe lub ciągłe testy ciągłości, jest zasilany z baterii 9 V i ma duży czytelny wyświetlacz LCD. Jest sprzedawany z odpornymi i trwałymi przewodami pomiarowymi o długości 200 cm. Nabywca otrzymuje indywidualne świadectwo kalibracji przyrządu dokonane przez NIST.

    Specyfikacje Techniczne

    CONTROLS

    ON/OFF Battery Bus Cut-off
    Slide Switch ON SIDE OF CASE

    ON: Energizes instrument and LCD displays Software Version then GO A with AUTO indication (Default)

    OFF: Isolates battery and DC voltage from instrument controls and circuit. Use for transport and storage

    TEST Pad
    With Test Leads installed: Press once & Release.
    Measurements performed automatically


    In conjunction with MODE changes from Auto operation to Continuous

    MODE Pad
    Steps through Auto/Voltage ranges with each press of MODE Pad:

    • AUTO: Default automatic resistance range & Voltage control
    • <10V: Manual Operation 0.01 to =10V Test Voltage;
      • Resistance Range: 0.01E-1 to 9.99E9 O
    • 10V: Manual Operation at 10V (Nominal, Semi-Constant)
      • Resistance Range: 0.98E4 to 9.99E10 O
    • 100V: Manual Operation at 100V (±<5V) Constant Voltage
      • Resistance Range: 0.98E6 to 9.99E12 O
      • When data in HOLD, press MODE to terminate HOLD without changing operational mode
      • Press MODE with TEST to change from Auto to Continuous
      • Used to measure lead resistance (NULL)
      • Used by Prostat Authorized Technicians for Voltage Calibration

    CONNECTIONS

    Positive (+): Test Voltage (RED) – Supplies test voltage to electrodes/fixtures

    Negative (-): Current sensing (BLACK) – Conducts current from electrode, fixtures or Ground to instrument

    Chassis: Shielding connection to chassis (WHITE) – Reduces transmitted energy and effect on current measurement

    Note: ¾ inch spacing between RED and BLACK accommodates dual banana BNC adapters

    INDICATION

    Colored LED’s indicate instrument operational MODE and Test Voltage (YELLOW) used for the current measurement, as well as measurement completion (GREEN LED).

    • AUTO: ON during automatic operations; OFF in Manual mode
    • <10V
    • 10V
    • 100V
    • GREEN LED: Measurement hold

    TYPICAL TOLERANCES

    1Nominal performance by range:

    0.01E- 1 – 1.0E 0 O <±10%, ±2 Counts
    1.0E 0 – 9.99E10 O <±2%, ±2 Counts
    1.0E11 – 9.99E12 O <± 10%, ±4 Counts

    TEST VOLTAGES

    Automatically selected and controlled in AUTO mode. May be manually selected by pressing MODE pad in the following order:

    <10V Variable based on resistance load:

    • Provides 0.001 to =10V
    • Functional in AUTO within range 0.01 O - <1.0E+4 O
    • Manual Operation Resistance Range: 0.01E-1 to 9.99E+9 O

    10V Constant Voltage (Under Load):

    • Test Voltage Varies ± <5% in AUTO or Manual Operations
    • Functional in AUTO within range 1.0E+4O - <1.0E+6 O
    • Manual Operation Resistance Range: 0.9E+4 to 9.99E+10 O

    100V Constant Voltage (Under Load):

    • Test Voltage Varies ± <2% in AUTO or Manual Operations
    • Functional in AUTO within range 1.0E+6 O - <1.0E+13 O
    • Manual Operation Resistance Range: 0.90E6 to 9.99E12 O
      Returns to Auto Mode

    MODES OF OPERATIONS

    GO A: Performs all automatic and manual voltage select functions, stops and displays measurements after Electrification Period (EP) is complete, then displays data with Green LED ON for 10 seconds.

    GO C: Performs all automatic and manual voltage select functions, continuously displays measurements until the operator presses MODE or TEST pads. GO C disables electrification period controls.

    POWER

    One 9V alkaline transistor battery; battery life > 50 hours

    DIMENSIONS

    7.25 in. (184 mm) x 4.3 in, (109 mm) x 1.4 in.

    WEIGHT

    13.2 oz. (375 gram) with battery installed

    NOTES

    1Tolerance and accuracy measurements were conducted under controlled conditions with close tolerance reference resistors.

    Do not attempt to open instrument case:

    • No internal operational parts or adjustments
    • Provides access to 100DCV power supply
    • Damage to instrument and environmental seals may occur
    • Will void warranty
    • Store instrument in case and dry environment

    Pobieranie Plików

    User Manuals

    Nazwa Dokumentu
    Język
    Data Wydania
    Rozmiar


    English
    2016-02-22
    4,680 KB

    Data Sheets

    Nazwa Dokumentu
    Język
    Data Wydania
    Rozmiar


    English
    2016-02-22
    476 KB

    Sales Sheets

    Nazwa Dokumentu
    Język
    Data Wydania
    Rozmiar


    English
    2016-02-26
    1,094 KB