PFK-100 Electrostatic Field Meter Set
Choose your language
This will change the language of the description for this product. It won't change the language of the site or other products.
  • PFK-100 Electrostatic Field Meter Set
    Measure fields and voltage generation and balance ionizers
    • Measure range & polarity of electrostatic fields in 1 volt or 10 volts increments
    • Balance Ionizers per ANSI/ESD SP3.3 Periodic Verification
    • Measure Ionizer Decay time as per ANSI/ESD S3.1 and ANSI/ESD SP3.3.
    • Measure Body Voltage Generation and Decay
    • Use with a datalogger to record measurements & create reports
    • Compatible with the Autoanalysis System
    • Accuracy of ± 2%
    • Battery Operated
    Balance ionizers per ESD SP3.3
    A Complete Instrument Set for Electrostatic Measurements
    Prostat’s innovative PFK-100 set was the first instrument combination of its kind. It includes Prostat's unique PFM-711A dual range field meter, the original CPM-720A portable charged plate monitor assembly and PCS-730 ±1 kV charging source.

    With this instrument set you can measure electrostatic fields, analyze ionizer performance and assess the voltage generation of materials, equipment and personnel.

    Electrostatic Field Meter
    Locate and Measure Static Charge
    The battery operated PFM-711A Field Meter is a compact stabilized "electronic chopper" design with accuracy of ±2% at ambient conditions (23ºC and 30%Rh). This advanced design allows it to be used in ionized environments without drifting. It features automatic polarity indication, a measurement "hold" button, low battery indicator, high and low ranges, distance ranging lights for accurate and repeatable measurements, manual zero control and a ground snap. The PFM-711A offers the user two ranges of operation:

    • 0 – 1,999V in 1 Volt increments with <±2% error, and
    • 0 – 20,000V in 10 Volt increments with <±5% error up to 5kV

    With the supplied analog output cable, it can be used in conjunction with an X-Y plotter or any analog data-recording device. The front panel analog output jack provides a 1 volt output corresponding to 10kV, which is independent of the selected meter range and indication.

    Balance & Monitor Air Ionization on Equipment
    A Portable Charge Plate Monitor
    The CPM-720A Charge Plate Assembly is 3.25 inches square. It attaches to the PFM-711A field meter for ionizer balancing per ANSI/ESD SP3.3 Periodic Verification, voltage or charge generation and voltage suppression analysis.

    Performace studies indicate the CPM-720A 3.25 inch plate has a strong correlation to the CPM-760A 6 inch Charge Plate Monitor.

    Measuring Decay Performance of Ionizers and Materials
    Charge It Up!
    The PCS-730 ±1 kV Charging Source is used to charge the CPM-720A to ±1,000 volts to measure ionizer decay time as required by both ANSI/ESD S3.1 and ANSI/ESD SP3.3.

    These three instruments are match calibrated to work together for accurate and efficient auditing.

    Balance & Monitor Air Ionization on Equipment
    Use it with an X-Y Plotter, Strip Chart Recorder or Digital Logging device
    The PFK-100 Field Meter Set can be used for voltage generation and decay analysis in conjunction with a variety of data recording instruments. Prostat’s PGA-710B Autoanalysis System® is a most unique electrostatic data analysis device. It records, plots, analyzes and automatically constructs reports of body voltage generation, electrostatic decay, voltage retention, ionizer performance and other static measuring functions. The combination of Prostat’s PFK-100 Set and PGA-710B Autoanalysis System® is the most up to date instrument collection for meeting today’s ANSI/ESD S20.20 and IEC 61340-5-1 ESD Program standard requirements.

    Technical Specifications

    PFM-711A FIELD METER

    METER DISPLAY

    3-1/2 digit Liquid Crystal Display with 0.4" digit height. Automatic polarity, HOLD and LOW BATTERY indicators.

    OUTPUT

    Analog signal output and 30 inch two conductor cable provided. ± 10.0KV meter reading equals ± 1.0 volts output.

    RANGE

    High Range 0 V to ± 19.99 KV; least significant digit indicates tens of volts at one inch distance.
    Low Range 0 V to ± 1,999 V; least significant digit indicates 1 volt at one inch distance.
    Measures higher voltages at greater distances, e.g., at two inches double indicated voltage, at four inches multiply indicated voltage by four.

    RANGE LIGHTS

    Red "Bulls Eye" at one inch distance

    ACCURACY & ENVIRONMENT

    ± 2% at ambient conditions ( 23ºC and 30% Rh).
    ± 5% at 0 - 50ºC and 0 - 85% Rh (non-condensing).
    Accuracy unaffected by the presence of air ionization.

    RESPONSE

    Digital display updates three (3) times per second.
    Analog Output Time Constant: Either Range 0.1 sec.
    Display Time Constants: High Range 0.2 sec; Low Range 2.0 sec

    CONTROLS

    Three position slide switch: KV/INCH - OFF - V/INCH
    Sample/HOLD push button, and ZERO adjust knob.

    GROUNDING

    Meter circuit grounded through the conductive case and 10 mm snap fastener mounted on back of case.

    POWER

    9 VDC alkaline battery. Battery life minimum 40 hours.

    DIMENSIONS

    2.4" wide x 4.2" long x .9" deep (1.3" deep with zero knob and snap fastener).

    WEIGHT

    5 ounces, with battery

    PCS-730 CHARGING SOURCE

    INPUT POWER

    9 Volt Alkaline Battery. Battery life in excess of 40 hours continuous operation.

    OUTPUT

    ± 1,000 volts DC Minimum, Current limited to less than 1 Microamp.

    OUTPUT

    Female banana jack provided with mating contact rod.

    GROUNDING

    10mm female snap fastener on rear of case. Note that wand must be installed and unit grounded for proper operation.

    SIZE

    2.5"W x 4"L (4.2"L with jack) x 1.5"D (1.8"D with switch and snap)

    WEIGHT

    6 oz (with battery)

    CPM-720A CHARGE PLATE ASSEMBLY

    ISOLATED PLATE

    Stainless Steel parallel plates, 3.25 inches square. Auxiliary female jack installed.

    CAPACITANCE

    Plate Capacitance 10 picofarads (pF) ± 1 pF
    Note: Plate capacitance is 15.8 pF when mounted to PFM-711A Filed Meter

    RANGE

    0 to ± 6 KV at a plate separation of 0.60 inch.

    ACCURACY

    ± 2% at 1,000 volts. Calibration adjustment screw provided.

    GROUNDING

    Through conductive case and snap fastener of Model PFM-711A.

    SIZE

    3.25"W x 3.25"L x .9"D (1.0"D with jack).

    WEIGHT

    8 oz.