The Autoanalyzer connects to a Field meter's analog output and lap top computer's USB using provided cables. Its Autoanalysis Applications software converts your instruments into a digital chart recording system with automatic analysis and reporting features.
The PGA-710B will perform measurement and recording functions, provide data analysis, generate charts, then construct and print out complete reports, including the facility's ambient temperature and relative humidity during each test.


The PGA-710B will calculate the ±3-Sigma ranges of Walking and Standing body voltages in your facility, graphically plot the percent probability of equaling or exceeding specific body voltages in the process, and calculate the maximum, minimum and average of voltage generation or decay times.

Technical Specifications
SIZE
WEIGHT
INPUT
OUTPUT
SAMPLING RATE
FILE LIMIT
BATTERY CONSUMPTION NOTES
- During Sleep Mode (Main Power Battery Switch ON, unit OFF): 8 – 10ma
Panel key pad is energized and unit is in standby mode. - During Normal Operations: 108ma
Unit is operating in remote or computer mode - Computer USB Battery Charge: 100ma
Operating in computer mode and receiving 100ma current from USB port reduces battery drain rate to 8ma. - Battery Charge from AC/DC Charger: 280ma
Charge battery with Main ON, OFF, or during operations
TEMPERATURE & RELATIVE HUMIDITY SENSOR
Sensor calibration is “fixed” based on materials, components and construction. It combines capacitive-polymer sensing technology with a measurement method that eliminates temperature correction and end user calibration. Once manufactured, the sensor’s calibration is not directly adjusted. The unit performs within parameters ±2% accuracy. Specifications are:
TEMPERATURE
Range: -30 to + 85°oC (-22°F to 185°F)
Accuracy: ± 0.40 °C (»1 °F)
Response Time: 50 seconds in slow moving airHUMIDITY
Operating Range: 0 – 100 percent (%)
Accuracy: ±2.0% Rh, 0-100% non-condensing
Linearity: ±0.5% Rh
Response Time: 25 sec-slow moving air 25°C (77 °F)
Recovery Time (from Condensation): 10 seconds
Stability: ±0.5% Rh/yearSYSTEM REQUIREMENTS
- Microsoft® Windows® XP, Vista, Win7 32-bit, Win7 64-bit, Win8 32-bit, Win8 64-bit, Server 2003, Server 2008 or Server 2012
- 90 MHz Intel Pentium-class processor, or an AMD Opteron, AMD Athlon64 or AMD Athlon XP Processor
- 32 MB of RAM, 96 MB Recommended
- 110 MB of hard disk space required, 40 MB additional hard disk space required for installation (150 MB total)
- 1024 x 768 with 256 colors
- Microsoft® Data Access Components 2.6
- Microsoft® DirectX 9b
- Instrument input limits to ± 2 volts
What's Included
- PGA-710B Autoanalyzer
- PGA-710 USB Cable
- PGA-710 Analog Cable
- PGA-710 Charge Generation Lead
- PGA-710CC Input Shorting Shunt
- Custom Carrying Case
- PFA-861H Footwear Auditor Handle
- Application Software
- User Manual
- How to Measure Manual