Call 630-238-8883
Prostat Corporation
 
 Home > Products > Professional ESD Auditing Kits > PGA-710 Kit Autoanalysis System Kit
 

PGA-710 Kit Autoanalysis System Kit

PGA-710 Autoanalysis System Kit

Larger Image Large Image

 

Compatibility

Compatible with Windows USB Connection

Note: The Autoanalysis Application Software may not be compatible with some Windows 7 64-bit versions.

Measure, Record, Analyze & Report Electrostatic Voltage Generation and Decay Performance on:

  • Footwear and Flooring Combinations
  • Carts and Chairs
  • Packaging Materials & Systems
  • Production Aids
  • Worksurface Voltage Supression
  • Ionization Offset Voltage & Decay Performance
  • Production Aids & Materials
  • Record Process Equipment Field Voltage

System Requirements:

  • Microsoft® Windows® 98, NT® 4.0 Service Pack 6a, 2000, ME, XP or Server 2003.

  • 90 MHz Intel Pentium-class processor, or an AMD Opteron, AMD Athlon64 or AMD Athlon XP Processor

  • 32 MB of RAM, 96 MB Recommended

  • 110 MB of hard disk space required, 40 MB additional hard disk space required for installation (150 MB total)

  • 800 x 600 or higher-resolution display with 256 colors

  • Microsoft® Data Access Components 2.6

  • Microsoft® DirectX 9b

  • Instrument input limits to ± 2 volts

 


Features & Overview
What's in the Kit
Find a Reseller
Kit Selection Chart

Add to Favorites Add to Favorites  Email this Page Email this Page  Printable Version Printable Version

Overview Specifications What's Included  
 
Overview

The PGA-710 is a unique electrostatic data analysis device for use with Prostat’s PFK-100 Fieldmeter/Charge Plate Monitor Set. It records, plots, analyzes and automatically constructs reports of body voltage generation, electrostatic decay, voltage retention, ionizer performance and other static measuring functions. Its analytical features document and automatically calculate projected levels of typical Human Body (HBM) voltages. It helps determine the risk of equaling or exceeding damaging or hazardous HBM discharge voltages in static sensitive facilities.

The Autoanalyzer links to a Field meter’s analog output and lap top computer’s USB using provided cables. Its Autoanalysis Applications software converts your instruments into a digital chart recording system with automatic analysis and reporting features. The PGA-710 will perform measurement and recording functions, perform data analysis, generate charts, then construct and print out complete reports, including the facility’s ambient temperature and relative humidity during each test.

The PGA-710 can be used as a freestanding data logger or recorder for later downloading to your computer. It will communicate with your computer via USB or RS-232 COM port.

The PGA-710’s unique software will instantly perform mathematical and statistical functions to assist ESD Program Managers and Plant Auditors in defining strengths and weaknesses of the ESDS device transport and handling process. The PGA-710 will calculate the 3-Sigma ranges of Walking and Standing body voltages in your facility, graphically plot the percent probability of equaling or exceeding specific body voltages in the process, and calculate the maximum, minimum and average of voltage generation or decay times.

The PFK-100 set includes Prostat's unique PFM-711A dual range field meter, CPM-720A charged plate monitor assembly and PCS-730 ±1 kv charging source. With this instrument set you can measure electrostatic fields, analyze ionizer performance and assess the voltage generation of materials, equipment and personnel.

The battery operated PFM-711A Field Meter is a compact "electronic chopper" design with accuracy of +/- 2% at ambient conditions (23ºC and 30%Rh). It features automatic polarity, measurement "hold" button, low battery indicator, high and low ranges, distance ranging lights for accurate and repeatable measurements, manual zero control and a ground snap. With the supplied analog output cable, it can be used in conjunction with an X-Y plotter or any analog data-recording device.

The CPM-720A Charge Plate Assembly is 3.25 inches square. It attaches to the PFM-711A field meter for ionizer balancing per ANSI/ESD-S3.1, voltage or charge generation and voltage suppression analysis.

The PCS-730 +/- 1 kV Charging Source is used to charge the CPM-720A to +/- 1,000 volts to measure ionizer decay and material decay. These three instruments are match calibrated to work together for accurate and efficient auditing.

 
 
You are here: Home > Products > Professional ESD Auditing Kits >  Autoanalysis System Kit Top of the Page Top
 
Prices are FOB Bensenville, Illinois USA and do not include applicable sales tax, duties, or shipping charges. Prices are slightly higher outside the United States. Pricing, specifications, availability and kit configuration subject to change without notice. PROSTAT® cannot be responsible for errors in typography or photography.

 

Request a Quote
Request a Quote for the  Autoanalysis System KitRequest a quote for the PGA-710 Kit and receive it within 24 hours! Or speak with a Sales Representative at 630-238-8883.
Request your Quote

 

ESD Answer Button
ESD Answer ButtonThe ANSWER BUTTON lets you ask questions about making ESD audit measurements, procedures, instrument capabilities and applications..
Ask your ESD Question


Testing to ESD Standards
  • ESD SP3.1 Ionization
  • ESD SP3.3 Ionizer Verification
  • ANSI/ESD STM97.2 Body Voltage Generation

Included with the following:

Kit Selection Chart

Kit Selection ChartThis Kit Selection Chart can help you choose which Professional Auditing Kit will meet your needs!

Learn more


Package Dimensions
Weight: 14 lbs (6.4 kg)
Length: 18.5 Inches (47 cm)
Width: 7.5 Inches (19 cm)
Height: 3.5 Inches (8.5 cm)

Download our Product Catalog
Prostat Catalog
Browse the latest catalog for our products and accessories.
Download now

 

 

Need help? Call us at 1-855-STATIC1 (782-8421) Option 1

Prices are FOB Bensenville, Illinois USA and do not include applicable sales tax, duties, or shipping charges. Prices are slightly higher outside the United States. Pricing, specifications, availability and kit configuration subject to change without notice. PROSTAT® cannot be responsible for errors in typography or photography.

© PROSTAT® Corporation. All rights reserved. Privacy Statement | Warranty Policy | [+] Feedback | Sitemap